Electrical buying guides
Straight answers on what to buy for wiring, earthing and fittings in Bengaluru homes: which size, how much, and what it costs.
Straight answers on what to buy for wiring, earthing and fittings in Bengaluru homes: which size, how much, and what it costs.
Plan switch boards room by room before the walls are chased. Typical sizes are an 8 module main board in each bedroom, a 12 module board in the hall, 3 to 4 module bedside boards, 6 module kitchen counter boards and 3 to 4 module boards for the AC, geyser and washing machine. Fix switch boards about 1.2 to 1.35 m (4 to 4.5 ft) above the finished floor and add one or two spare modules to every board.
4 min read
Modular boxes are named by how many modules (switch widths) they hold. The common sizes are 1–2 module (about 3x3 inches), 3 module (3x4), 4 module (3x5), 6 module (3x8), 8 module (5x5 square or 3x9 in one row), 12 module (5x8), 16 module (about 6x9) and 18 module (8x8), all roughly 50 to 60 mm deep. Count the switches and sockets on each board, add one or two spare modules, and always use the same brand and range for the box and the plate.
4 min read
GI (galvanised iron) modular boxes are stronger, hold the plate screws firmly and suit brick, block and concrete walls, which covers most of a Bengaluru home. PVC boxes don't rust and don't need earthing, so they suit bathrooms, utility areas and damp outside walls. Both cost about the same, so choose by where the box goes.
2 min read
Before the slab is cast, every ceiling fan, light and spotlight point needs its box and conduit fixed and tied to the steel. Use HMS (heavy) pipe, seal every joint and close every box and pipe end, because nothing can be added once the concrete is poured. Getting it right costs very little; fixing a missed point later means breaking the ceiling.
6 min read
A fan box is a round box cast into the roof slab at every ceiling fan point. Its hook carries the fan's weight for years, and its side openings take the conduit pipes. Use a heavy metal fan box with a proper hook, one for every room that might ever have a fan, fixed level and centred before the slab is cast. A heavy fan box costs very little, while adding a fan point after casting means breaking the ceiling.
4 min read
A concealed wiring job uses about a dozen conduit fittings: bends to turn corners, collars to join lengths, junction boxes where pipes meet or branch, fan and spotlight boxes in the slab, solvent to seal joints, and saddles or clamps to hold surface pipes. Match every fitting to your pipe size (19/20 mm or 25 mm), use heavy (HMS) fittings in slabs and walls, and order them with the pipe so the work never stops for a missing part.
5 min read
FR wire resists catching fire and stops a flame running along it. FRLS (also written FR-LSH) does that and also gives off far less smoke, which is what actually harms people in a fire. HFFR (also called LSZH or ZHFR) contains no halogens at all, so it releases almost no toxic gas. For most Bengaluru homes and apartments, FR-LSH is the best value: from the same brand it costs only about 3% more than FR-grade wire.
5 min read
For most 1 and 1.5 ton split ACs, run a separate circuit in 2.5 sq mm copper wire (phase, neutral and earth) protected by a 16 A MCB. For a 2 ton AC, or any run longer than about 30 metres, use 4 sq mm wire with a 20 A MCB. Always check the maximum current printed on your AC's rating plate before you buy.
6 min read
Use 19 mm (often called 20 mm) PVC conduit for lighting and fan circuits, and 25 mm for socket, AC and geyser circuits, or wherever two circuits share a pipe. Choose HMS (heavy) pipe for anything cast into a concrete slab or concealed in walls, and MMS (medium) for surface runs. Don't pack a pipe more than about 40% full, so the wires pull easily and stay cool.
4 min read
Every house needs at least one good earth pit, and two are safer: one can fail without leaving the house unprotected. Use a GI pipe or copper plate electrode in a pit packed with charcoal and salt that is kept moist, and connect it to the main distribution board with 8 SWG bare copper earth wire. Ask your electrician to test it and aim for an earth resistance below about 5 ohms.
5 min read